Type 441 (class 2) 1.1/1.1KV
Applications :
- These Class 2 cables are designed for many uses, suitable for trailing and also suitable for reeling applications, have one central pilot and a semiconductive cradle supporting and protecting the power cores,which makes these cables less likely to be damaged from crushing and squashing.
Standards :
Construction :
-
3×Conductors Flexible stranded tinned annealed copper conductor. Insulation EPR. Conductor Screen Semiconductive elastomer. Cradle Separator Semiconductive PCP. Overall Core Screen Semiconductive PCP filling and covering. 3×Interstitial Earth Conductor Semiconductive PCP covered flexible stranded tinned copper conductor. 1×Central Extensible Pilot EPR covered flexible stranded tinned copper conductor. Textile Reinforcement Open-weave braid reinforcement. Sheath Heavy duty PCP sheath. Heavy duty CPE/CSP sheath can be offered upon request.
Dimensions and Weight :
-
Nominal
Conductor
AreaStrand Size Insulation
ThicknessEarth Conductor Pilot Conductor Thickness
of SheathNominal
Overall
DiameterNominal
WeightStrand Size Thickness
of CoveringStrand Size Thickness
of Coveringmm² No/mm mm No/mm mm² No/mm mm mm mm kg/100m Type 441.1 Class2 6 84/0.30 1.5 33/0.30 0.8 24/0.20 0.8 3.8 28.5 111 10 77/0.40 1.5 51/0.30 0.8 24/0.20 0.8 3.8 31.1 136 16 126/0.40 1.6 81/0.30 1.0 24/0.20 0.8 3.9 34.1 176 25 209/0.40 1.6 81/0.30 1.0 24/0.20 0.8 4.2 37.9 231 35 285/0.40 1.6 81/0.30 1.0 24/0.20 0.8 4.4 41.2 274 50 380/0.40 1.7 120/0.30 1.0 40/0.20 0.8 4.9 45.9 349 70 203/0.67 1.8 39/0.67 1.0 40/0.20 0.8 5.3 52.2 481 95 259/0.67 2.0 48/0.67 1.0 40/0.20 0.8 5.8 56.7 579 120 336/0.67 2.1 60/0.67 1.0 40/0.20 0.8 6.3 62.7 724 150 427/0.67 2.3 77/0.67 1.2 40/0.20 0.8 6.7 68.3 881 185 518/0.67 2.5 91/0.67 1.2 40/0.20 0.8 7.3 74.9 1049 240 672/0.67 2.8 119/0.67 1.2 40/0.20 0.8 8.0 83.3 1329 300 854/0.67 3.0 156/0.67 1.4 40/0.20 0.8 8.7 91.2 1629